Once enabled, the functionality on the TURBO Panels is the same as on the VISTA P-Series Systems. It is also set, by default, as a silent police panic. But on the VISTA-TURBO Panels, this is programmed as Zone 999. The function key is the second of the four (4) function keys from the top. This silent police panic is triggered by pressing both the and keys together, or by pressing and holding the function key on the left side of the keypad. On the VISTA P-Series Systems, Zone 99 is, by default, set as a silent police panic. ![]() Once the panic key is programmed, pressing both the and keys together or pressing the function key can initiate the panic. But in the end, the functionality is very similar. These panels differ slightly in the way that keypad panic keys are programmed. On the VISTA-TURBO Panels, such as the Vista-128BPT or Vista-250BPT, this is programmed as Zone 995, and it is enabled by default. The function key is the top of the four (4) function keys at the left side of the keypad. This audible fire panic is triggered by pressing both the and keys together, or by pressing and holding the function key on the left side of the keypad. However, for Alarm Grid customers who choose to use this panic it is suggested that it be set as an audible Fire Panic. On the VISTA P-Series Systems, Zone 95 is, by default, not programmed. However, the associated single-button panic inputs should still work as intended, if they are enabled. Because of this defect, any affected 6150 Keypad will have its dual-button triggers for panics not work correctly. When an affected keypad is programmed to enable its dual-button press panic functions, the device will not function as intended. Resideo states that the issue in question affects the panic functions of the keypad. ![]() For that reason, Resideo is instituting a shipping and manufacturing hold on the Honeywell 6150 Keypad, effective immediately. ![]() This date code is relevant to any Honeywell 6150 Keypad manufactured between Apand J. It is unknown if this issue affects all 6150 Keypad with this date code prefix or just certain models within the batch. Any 6150 Keypad affected by this issue that was purchased through Alarm Grid should be returned to us for a free replacement.Īccording to Resideo, this issue may affect Honeywell 6150 Keypads that have a date code starting with "C107". This issue only affects 6150 Keypads manufactured within a certain time period. Resideo has announced that there is an issue affecting certain Honeywell 6150 Keypads.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |